ThermaX PRO—2nd-Generation R290 Hydro Split Heat Pump: High-Temperature, Ultra-Quiet, A+++ Efficiency for Heating, Cooling and DHW
Introduction
ThermaX PRO is Shenling’s next-generation hydro split heat pump engineered for European installers, distributors and commercial end-users who demand top-tier seasonal efficiency, high-temperature output and smart IoT control. Built around the low-GWP refrigerant R290, the ThermaX PRO delivers A+++ performance at both 35°C and 55°C, supports domestic hot water up to 75°C, operates to −25°C ambient and includes a full smart control suite (7" touch display, Wi-Fi/LAN, OTA, cloud monitoring). This product line balances efficiency, reliability and quiet operation — designed for floor heating, radiators, fan coils and DHW systems.
Smart control: 7″ Android touch UI + Wi-Fi/LAN, app & web portal, OTA updates, energy metering ±5% tolerance.
Low-GWP refrigerant R290 for better environmental performance and lower lifecycle carbon impact.
Product Overview / Why Choose ThermaX PRO
ThermaX PRO is designed to solve two common installer problems: delivering comfortable heating/DHW at high water temperatures while maintaining top seasonal efficiency, and minimizing callbacks by combining proven branded components with robust leak protection and comprehensive remote diagnostics. The unit is suitable for new builds, retrofit projects where radiators require higher temperatures, and projects that prioritize environmental credentials (R290) and future-proof connectivity.
Key Features & Descriptions
High-Temperature Performance (DHW & Heating)
ThermaX PRO supports water outlet temperatures up to 80°C(with backup heater), making it compatible with DHW cylinders and radiator systems that demand higher temperatures — ideal for retrofits and mixed-use buildings where boosting temperature is required.
Feature: R290 Refrigrant
Outstanding Seasonal Efficiency (ErP A+++)
Designed to reach A+++ seasonal performance at both 35°C and 55°C, ThermaX PRO reduces operating costs and improves lifecycle emissions — a major selling point for energy-focused commercial clients and specification-led projects.
Cold-Climate Reliability
Operates down to −25°C ambient. Heating capacity retention is strong at low temperatures: ≥100% at −7°C, ≥85% at −15°C and ≥75% at −20°C (model dependent). This ensures dependable performance in colder European climates.
Figure: Powerful Heating Output
Ultra-Quiet Operation
Aerodynamic blade design, sound chamber insulation and two-stage vibration isolation deliver industry-leading low noise: for example, 46 dB(A) @1 m, 39 dB(A) @3 m, meaning easy siting near property boundaries or sensitive areas.
The 24dB(A) figure is based on the data tested on the 5kW model in night mode.
Feature: Ultra-silent axial fan design
Feature: Two-stage vibration isolation design
Feature: Soundproof Chamber with cotton
Quality Components & Leak Safety
Built with trusted components to reduce service risk and extend life:
Danfoss — plate heat exchanger.
Shimga/Grundfos — primary water pumps.
Sanhua — service & expansion valves.
Shimge — alternative pump options.
Added protections include a gas separator, refrigerant leakage detection and dedicated leakage error handling.
Smart Control & IoT
7-inch Android touch controller with multi-language UI, weather compensation, dual-zone temp control and real-time energy metering (±5% tolerance). Units support Wi-Fi/LAN, cloud management (app + web), OTA firmware updates and remote fault alarms — enabling remote commissioning, monitoring and service diagnostics.
Feature: WIFI&Lan communication
An energy-metering function is able to calculate the share of energy derived from renewable sources. End users have the option to receive customized energy analyses through an app, user interface, and web portal.
Feature: Energy Metering
Based on:
High accuracy logic algorithm
Precise sensor signaling
Flexible Applications
Domestic hot water (DHW) systems
Underfloor heating (20–70°C supply range when configured)
Radiator heating (45–75°C capability)
Fan coil systems (30–45°C typical) (Actual configuration and setpoints should follow engineering data book for model-specific details.)
ThermaX PRO R290 Hydro Split Heat Pump-pic-3-4-in-1-one-stop-heating-solution
Technical Specifications (high-level)
Refrigerant: R290 (propane) – low GWP, high thermodynamic efficiency.
Power / model range: 5 / 7 kW (1-phase); 10 / 12 / 15 kW (3-phase).
Min ambient operating temp: −25°C.
Max water outlet temp: 75°C without backup heater/80°C with backup heater.
Strong specification: A+++ at 35°C/55°C simplifies tender wins for low-carbon projects.
Reduced service visits thanks to branded components and remote diagnostics.
Clear angles for marketing: high-temp DHW capability, low-GWP refrigerant, quiet operation, and IoT energy analytics.
FAQs
Q1: What maximum water temperature can ThermaX PRO reach for DHW? A: ThermaX PRO supports water outlet temperatures up to 80°C with backup heater, making it suitable for domestic hot water cylinders and radiator systems that need higher supply temperatures.
Q2: Is ThermaX PRO efficient at high flow temperatures? A: Yes — the product line is engineered to achieve A+++ seasonal energy efficiency at both 35°C and 55°C operating points, delivering excellent performance even at elevated flow temperatures.
Q3: Can ThermaX PRO operate in very cold climates? A: Yes — the unit operates down to −25°C ambient with strong capacity retention (≥100% at −7°C; ≥85% at −15°C; ≥75% at −20°C), depending on the model.
Q4: What refrigerant does it use and are there safety considerations? A: ThermaX PRO uses R290 (propane), a low-GWP refrigerant with excellent efficiency. Installers must follow local codes for A3 refrigerants (flammable) and ensure qualified handling and compliant ventilation.
Q5: Does the unit support remote monitoring and OTA updates? A: Yes — features include a 7″ touch controller, Wi-Fi/LAN, app & web portal, remote fault alarms and OTA firmware updates for improved serviceability and performance tracking.
Q6: How quiet is ThermaX PRO? A: The ThermaX PRO series is engineered for ultra-quiet operation: sample max sound pressure levels include 46 dB(A) @1 m and 39 dB(A) @3 m, with acoustic design features to minimize noise in real installations.
Q7: What components are used inside the unit? A: The product uses high-quality, proven components including a Danfoss plate heat exchanger, Grundfos/Shimge water pumps and Sanhua valves to maximize reliability and simplify service.
Q8: What models and power ranges are available? A: ThermaX PRO is available in 5/7 kW (single-phase) and 10/12/15 kW (three-phase) variants to cover small residential to light commercial applications.
Q9: Does the unit include energy metering? A: Yes — it includes built-in energy metering with high-accuracy logic (tolerance ≤ ±5%), enabling installers and end users to track renewable energy share and consumption.
Q10: Is ThermaX PRO suitable for radiator retrofits? A: Yes — because of its high-temperature capability (up to 80°C) and robust low-temperature performance, ThermaX PRO is a strong option for radiator retrofits that need higher supply temperatures.
Specification
Technical Data
Outdoor unit
HPM-V50W/R3-C
HPM-V70W/R3-C
HPM-V100W/R3-C
HPM-V120W/R3-C
HPM-V150W/R3-C
General Data
Color
RAL8022
Min. Ambient temperature
°C
-25
Max. Ambient temperature
°C
45
Operational information: Heating
Heating output A7/W35 (EN 14511)
kW
3.3(2.56~5.32)
4.5(2.56~7.14)
6.3(4.54~13.44)
7.3(4.54~14.85)
8.3(4.54~17.10)
COP A7/W35 (EN 14511)
5.3
5.2
5.4
5.3
5.3
Heating output A7/W55 (EN 14511)
kW
3.3(2.64~5.15)
4.4(2.64~7.04)
6.4(4.29~12.69)
7.8(4.29~14.38)
8.4(4.29~16.46)
COP A7/W55 (EN 14511)
3.1
3.1
3.1
3.1
3.1
Heating output A2/W35 (EN 14511)
kW
1.9(2.28~5.23)
2.7(2.28~7.10)
4.9(3.82~13.05)
5.5(3.82~13.86)
6.2(3.82~16.03)
COP A2/W35 (EN 14511)
4.2
4.2
4.3
4.1
3.9
Heating output A2/W55 (EN 14511)
kW
1.9(2.23~5.05)
2.6(2.23~6.97)
4.8(3.24~12.15)
5.4(3.24~13.50)
6.4(3.24~15.59)
COP A2/W55 (EN 14511)
2.4
2.4
2.4
2.3
2.3
Heating output A-7/W35 (EN 14511)
kW
5(1.87~4.9)
6.7(1.87~7.06)
9(3.75~11.37)
10(3.75~12.59)
12(3.75~14.21)
COP A-7/W35 (EN 14511)
3.3
2.9
3.3
3.0
2.8
Heating output A-7/W55 (EN 14511)
kW
4.8(1.67~4.68)
6.9(1.67~6.49)
9(2.5~10.49)
10(2.5~11.65)
11(2.5~13.34)
COP A-7/W55 (EN 14511)
2.3
2.2
2.3
2.2
2.2
Nominal air volume flow
m³/h
≤3600
≤3600
≤4800
≤4800
≤4800
Operational information: Cooling
Cooling capacity A35/W18 (EN 14511)
kW
5.1
7.0
10.4
12.4
14.5
Electrical data
Rated voltage
V
230V
230V
400V
400V
400V
Electrical frequency
Hz
50
50
50
50
50
Protection rating (EN 60529)
IP
IPX4
IPX4
IPX4
IPX4
IPX4
Max. electrical power consumption (3-phasig)
kW
3.3
3.8
8.5
9.5
11.1
Dimensions/Weights
HxWxD
mm
975x1285x465
1100x1350x560
Net weight
kg
163
163
230
230
230
EU Directive on Energy Efficiency
Energy efficiency class
A+++
Energy efficiency class (Low-temperature application)
Xiangyang Airport in Hubei Province, China, has fully deployed ground support systems across its boarding bridges to reduce aircraft emissions and energy consumption. The systems,
VOC emission control is an unavoidable environmental challenge for the oil, gas, and petrochemical sectors. Large volumes of hydrocarbon vapors generated during tank breathing and
Every successful airport project begins long before installation. It starts with precision manufacturing, rigorous quality control, and a commitment to delivering reliable equipment on time.